ABB Αντικεραυνικό - Περιοριστής Υπερτάσεων SPD (OVR PV 40 600P TS)
Type 1 SPDs provide input protection for plants in areas with high levels of lightning strikes, and are typically installed in main distribution switchboards to protect against direct lightning strikes.
Benefits of the ABB OVR T1 range
Wide range
OVR T1 SPDs are available in multi-pole versions to be used in all applications. There are also single-pole versions to be assembled for maximum flexibility.
High impulse current
The impulse current of 25 kA per pole (10/350 μs wave) satisfies all requirements for overvoltage surge protection.
Signalling contact
It is possible to monitor the operational status of the SPD remotely via a 1 A dry exchange contact.
Co-ordination
OVR T1 SPDs are co-ordinated at zero distance from OVR Class 2 SPDs; they can therefore be installed next to each other without decoupling coils, for combined protection against direct and indirect lightning strikes.
Electronic arc ignition device
The early creation of the electric arc by this electronic device reduces the protection level Up to an optimum value, 2.5 kV.
Extinguishment of the follow-through current
OVR T1 SPDs contain a dedicated arc chamber for extinguishing the electric arcs following through from discharges. Thanks to this the SPD can open short-circuits up to 50 kA without the back-up fuse having to cut in.
Multi-pole versions with "1+1" and "3+1" schemes
Thanks to the "1+1" and "3+1" designs providing for a spark gap to earth, OVR T1 can be installed upstream of the RCD to protect against and prevent unwanted tripping. Combined-mode protection is provided, both common and differential.
Double terminals
OVR T1 allows an input and output cable to be connected for each pole, with a current up to 125 A. They allow connection distances to be reduced to a minimum and avoid bridges.
Combined Type 1 + Type 2 SPDs
These are very compact SPDs which protect both against direct and indirect lightning strikes. They are dedicated to applications where space is very limited (telecoms).
General Information
- Extended Product Type: OVR PV 40 600P TS
- Product ID: 2CTB803953R5400
- EAN: 3660308515353
- Catalog Description: OVR PV 40 600P TS
- Long Description: OVR PV 40 600P TS
- Ordering EAN: 3660308515353
- Minimum Order Quantity: 1 piece
- Customs Tariff Number: 85354000
Dimensions
- Product Net Width: 118 g
- Product Net Height: 82 mm
- Product Net Length: 61 mm
- Product Net Weight: 375 mm
Container Information
- Package Level 1 Width: 118 mm
- Package Level 1 Height: 82 m
- Package Level 1 Length: 61 mm
- Package Level 1 EAN: 3660308516527
Additional Information
- Product Main Type: T2
- Product Name: Surge Protective Devices
- Suitable For: To protect the systems against the transient over-voltage (lightning)
- Suitable for Product Class: OVR T1+2
Βάρος (κιλά) | 0.800000 |
---|---|
Κατάσταση | Καινούριο |
Brand | ABB |
Μοντέλο | OVR PV 40 600P TS |
Part Number | 3660308515353 |
Χρώμα | Λευκό |
Εγγύηση | 12 μήνες |